Manufacturer manual says: Do not put below.48 because it will burn out the anticipator. It appears to be already preset at 1.0 which is good. With safety a priority, I called the very helpful customer service at Atwood in Indiana to verify the exact thermostat model needed for the existing Atwood.
LITERATURE NUMBER MPD 31493 | ||||
hydro flameTM | ||||
Model 2H2C | ||||
Two Stage Furnace | ||||
9 | Digital Thermostat | |||
FOR TWO STAGE FURNACE | ||||
ENGLISH, FRANCAIS (et Canada) | •Installation •Operation | |||
Effective 1/08 |
THIS THERMOSTAT HAS BEEN DESIGNED TO OPERATE STANDARD AIR CONDITIONING UNITS IN CONJUNCTION WITH AN EXCALIBUR 2-STAGE FURNACE.
Screw Mounting Holes | |||||||||
Mode | Temperature | ||||||||
Display Set | Set | ||||||||
(OFF) OFF | HEAT (CHAUFFAGE) | M | |||||||
(CLIM) COOL | FAN (VENTIL.) | ||||||||
System Switch | |||||||||
*Note: Move jumper to | |||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | positions 3 and 4 for RVP | |
12VDC | NOT | +12VDC | RELAY | A/C | A/C | A/C | TH FROM | Unit. Discard jumper for | |
Ground | USED | COM | COM- | HI | LOW | FURNACE | |||
Dometic®. | |||||||||
* | PRESSOR | FAN | FAN |
THERMOSTAT INSTALLATION
Thermostat is very sensitive. HANDLE WITH CARE AT ALL TIMES.
Locate thermostat 48˝ to 54˝ above floor on an INTERIOR wall. Pick a dry area where air circulation is good. EXTERIOR wall location must have a 3/4˝ spacer between thermostat and exterior wall.
1.Be sure all electrical power has been disconnected from the air conditioner, furnace and the power supply.
2.Do not install the thermostat where there are unusual heating conditions: such as direct sunlight, heat producing appliances (television, radio, wall lamp, etc.)
or a furnace or air conditioner supply register.
3.ATTACHING THE WALL THERMOSTAT. Separate the thermostat body from the sub-base by gently squeezing the top and bottom. Pull wires through access hole in base plate. Attach thermostat sub-base to the wall at the desired mounting location. Mount the sub-base to the wall before connecting the wires.
System Slide Switch | SCROLL ORDER OF | OPERATION | |||||||
LEFT | RIGHT | DISPLAYED MODES | |||||||
COOL | OFF | HEAT | FAN | Scroll Order of Displayed Modes | Furnace Operation | ||||
• | AU | Furnace automatically switches between high and low BTU valve and high | |||||||
and low speed fan when cycling to satisfy set point. | |||||||||
• | HI | Furnace high BTU valve and high speed furnace fan cycle to satisfy set point. | |||||||
• | LO | Furnace low BTU valve and low speed furnace fan cycle to satisfy set point. | |||||||
• | HF | Furnace fan runs at high speed to circulate air. Air conditioner fan does not run. | |||||||
• | LF | Furnace fan runs at low speed to circulate air. Air conditioner fan does not run. | |||||||
COOL | OFF | HEAT | FAN | Scroll Order of Displayed Modes | Air Conditioner Operation | ||||
• | AU | Air conditioner automatically switches compressor and high and low speed fan when | |||||||
cycling to satisfy set point. | |||||||||
• | HI | Air conditioner compressor and high speed fan operate to satisfy set point. | |||||||
• | LO | Air conditioner compressor and low speed fan operate to satisfy set point. | |||||||
• | HF | Air conditioner fan runs at high speed to circulate air. Furnace fan does not run. | |||||||
• | LF | Air conditioner fan runs at low speed to circulate air. Furnace fan does not run. | |||||||
COOL | OFF | HEAT | FAN | Scroll Order of Displayed Modes | Fan Operation | ||||
• | HI | Air conditioner fan and furnace fan run at high speed to circulate air. | |||||||
• | LO | Air conditioner fan and furnace fan run at low speed to circulate air. | |||||||
COOL | OFF | HEAT | FAN | Scroll Order of Displayed Modes | Off | ||||
• | OF | No operation occurs. |
Specifications | Operating Voltage ...................... 9VDC to 18VDC | Room Temperature Range .............. | +55F to +90F |
Power Consumption ................................ 100mA | Room Temperature Display Range .. | +35F to +99F | |
Operating Temperature .................. -40F to +185F | Thermostat Accuracy ................................ +/- 1F |
Description
Atwood 7920-II
Atwood Hydro Flame Thermostat Manual
*NEITHER OF THESE KITS ARE APPLICABLE TO A 7920, ONLY TO A 7920-II*
Tune-Up Kit #1 Obsolete / No Longer Available:
Tune-Up Kit #2 Includes:
Item# 2 Burner Air Tube 35892
Item# 6 Door Latch 37912
Item# 7 Duct Cover, 4 Inch, 31361
Item# 8 Duct Adapter, 4 Inch, 31474
Item# 9 Duct Adapter, 2 Inch, 36688
Item# 20 Burner Plate Gasket 35890
Item# 24 Motor Mount Assembly 35879 NLA
Item# 27 OEM Ignition Module 31501
*Not Shown* Wiring Harness Kit 30230
Item# 28 Ignition Module Mounting Bracket 37951
Item# 29 Manifold 37391
Item# 30 OEM Motor 31036
Hydro Flame Furnace Manual
Item# 41 Thermostat, Heat Only, Brown, 38452 NLA
Item# 41 Thermostat, Heat Only, White, 38453
Item# 42 Gas Valve 31150
Item# 45 Vent Kit, 4 Inch, 35955
Item# 45 Vent Kit, 8 Inch, 35956
Item# 45 Vent Kit, 12 Inch, 35957 NLA
Atwood Hydro Flame Furnace Thermostat
Item# 51 Coil (Replacement for Item# 42 Gas Valve) 31000 NLA
*Not Shown* 2 Inch Heater Duct Hose